&Ns(>aRk    &<Pi}$:!Ng{   #  "$ %  :" 8 ')Lt *e yi (-o x ,. / !+5 13 46EJ27cw689>0D;=><A4H@BaCu?IEGHFK!'JL2QMF_DISK-8000-ES.typeDISK-8000-ES.severityDISK-8000-ES.responseDISK-8000-ES.impactDISK-8000-ES.descriptionDISK-8000-ES.actionDISK-8000-D5.typeDISK-8000-D5.severityDISK-8000-D5.responseDISK-8000-D5.impactDISK-8000-D5.descriptionDISK-8000-D5.actionDISK-8000-CY.typeDISK-8000-CY.severityDISK-8000-CY.responseDISK-8000-CY.impactDISK-8000-CY.descriptionDISK-8000-CY.actionDISK-8000-A3.typeDISK-8000-A3.severityDISK-8000-A3.responseDISK-8000-A3.impactDISK-8000-A3.descriptionDISK-8000-A3.actionDISK-8000-9H.typeDISK-8000-9H.severityDISK-8000-9H.responseDISK-8000-9H.impactDISK-8000-9H.descriptionDISK-8000-9H.actionDISK-8000-8D.typeDISK-8000-8D.severityDISK-8000-8D.responseDISK-8000-8D.impactDISK-8000-8D.descriptionDISK-8000-8D.actionDISK-8000-74.typeDISK-8000-74.severityDISK-8000-74.responseDISK-8000-74.impactDISK-8000-74.descriptionDISK-8000-74.actionDISK-8000-6R.typeDISK-8000-6R.severityDISK-8000-6R.responseDISK-8000-6R.impactDISK-8000-6R.descriptionDISK-8000-6R.actionDISK-8000-4Q.typeDISK-8000-4Q.severityDISK-8000-4Q.responseDISK-8000-4Q.impactDISK-8000-4Q.descriptionDISK-8000-4Q.actionDISK-8000-3E.typeDISK-8000-3E.severityDISK-8000-3E.responseDISK-8000-3E.impactDISK-8000-3E.descriptionDISK-8000-3E.actionDISK-8000-2J.typeDISK-8000-2J.severityDISK-8000-2J.responseDISK-8000-2J.impactDISK-8000-2J.descriptionDISK-8000-2J.actionDISK-8000-12.typeDISK-8000-12.severityDISK-8000-12.responseDISK-8000-12.impactDISK-8000-12.descriptionDISK-8000-12.actionDISK-8000-0X.typeDISK-8000-0X.severityDISK-8000-0X.responseDISK-8000-0X.impactDISK-8000-0X.descriptionDISK-8000-0X.actionFaultCriticalThe device may be offlined or degraded. A hot-spare disk may have been activated.The device has failed. The service may have been lost or degraded.A non-recoverable drive failure was detected by the device while performing a command.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorA hot-spare disk may have been activated.If a hot spare is available it will be brought online and during this time I/O could be impacted. If a hot spare isn't available then I/O could be lost and data corruption is possible.There have been excessive transient ZFS checksum errors on this disk.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultCriticalThe device may be offlined or degraded. A hot-spare disk may have been activated.It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.There have been non-recovered ZFS checksum errors on this disk.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorA hot-spare disk may have been activated.If a hot spare is available it will be brought online and during this time I/O could be impacted. If a hot spare isn't available then I/O could be lost and data corruption is possible.There have been excessive recovered medium write errors on this disk.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorA hot-spare disk may have been activated.If a hot spare is available it will be brought online and during this time I/O could be impacted. If a hot spare isn't available then I/O could be lost and data corruption is possible.There have been excessive recovered medium read errors on this disk.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultCriticalThe device may be offlined or degraded. A hot-spare disk may have been activated.It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.There has been a non-recovered medium write error.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultCriticalThe device may be offlined or degraded. A hot-spare disk may have been activated.It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.There has been a non-recovered medium read error.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultCriticalNo automated response will occur.The IO service to this device may have been lost or degraded.A path to the device has been unconfigured due to transport instability.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultCriticalThe device may be offlined or degraded. A hot-spare disk may have been activated.It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.A medium error was detected by the device that was non-recoverable.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultCriticalThe device may be offlined or degraded. A hot-spare disk may have been activated.The device has failed. The service may have been lost or degraded.A non-recoverable hardware failure was detected by the device.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultCriticalA hot-spare disk may have been activated.The disk has failed.One or more disk self tests failed.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorA hot-spare disk may have been activated.Performance degradation is likely and continued disk operation beyond the temperature threshold can result in disk damage and potential data loss.A disk's temperature exceeded the limits established by its manufacturer.Use 'fmadm faulty' to provide a more detailed view of this event. Ensure that the system is properly cooled, that all fans are functional, and that there are no obstructions of airflow to the affected disk. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorA hot-spare disk may have been activated.It is likely that the continued operation of this disk will result in data loss.SMART health-monitoring firmware reported that a disk failure is imminent.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.