#H& ;NRfyMS Y_ &  -@/XkP|V\bD  2aJ ]n!"5A $&  %) $t (*< +O ` '0u  -/ o .22 8 13> 4D  ,>. Aj68Rpgv7;||:<=Y_9Cek?AB 73@EDYDFn GjSAS-8000-CC.typeSAS-8000-CC.severitySAS-8000-CC.responseSAS-8000-CC.impactSAS-8000-CC.descriptionSAS-8000-CC.actionSAS-8000-AQ.typeSAS-8000-AQ.severitySAS-8000-AQ.responseSAS-8000-AQ.impactSAS-8000-AQ.descriptionSAS-8000-AQ.actionSAS-8000-94.typeSAS-8000-94.severitySAS-8000-94.responseSAS-8000-94.impactSAS-8000-94.descriptionSAS-8000-94.actionSAS-8000-8R.typeSAS-8000-8R.severitySAS-8000-8R.responseSAS-8000-8R.impactSAS-8000-8R.descriptionSAS-8000-8R.actionSAS-8000-7H.typeSAS-8000-7H.severitySAS-8000-7H.responseSAS-8000-7H.impactSAS-8000-7H.descriptionSAS-8000-7H.actionSAS-8000-6D.typeSAS-8000-6D.severitySAS-8000-6D.responseSAS-8000-6D.impactSAS-8000-6D.descriptionSAS-8000-6D.actionSAS-8000-5Y.typeSAS-8000-5Y.severitySAS-8000-5Y.responseSAS-8000-5Y.impactSAS-8000-5Y.descriptionSAS-8000-5Y.actionSAS-8000-43.typeSAS-8000-43.severitySAS-8000-43.responseSAS-8000-43.impactSAS-8000-43.descriptionSAS-8000-43.actionSAS-8000-3S.typeSAS-8000-3S.severitySAS-8000-3S.responseSAS-8000-3S.impactSAS-8000-3S.descriptionSAS-8000-3S.actionSAS-8000-25.typeSAS-8000-25.severitySAS-8000-25.responseSAS-8000-25.impactSAS-8000-25.descriptionSAS-8000-25.actionSAS-8000-1P.typeSAS-8000-1P.severitySAS-8000-1P.responseSAS-8000-1P.impactSAS-8000-1P.descriptionSAS-8000-1P.actionSAS-8000-0A.typeSAS-8000-0A.severitySAS-8000-0A.responseSAS-8000-0A.impactSAS-8000-0A.descriptionSAS-8000-0A.actionFaultMajorNone.Unsupported enclosure type may give unexpected system behavior.Unsupported enclosure type %.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorNone.Unsupported mixing of enclosure types within a chain may give unexpected system behavior.Unsupported mixing of enclosure types between % and %.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorNone.Path redundancy to associated disks is unavailable.Reverse side of chain of enclosures [%] is not connected to an HBA.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorNone.Too many cables are connected on one sas expander - one or more cables is redundant or incorrect.Too many cables attached to same sas expander. Unexpected cable % -> %.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMinorNone.Unbalanced enclosure chain depths may give degraded system performance.Chain of enclosures connected to HBA receptacle % is longer than chains connected to other HBA receptacles.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMinorNone.Having unused HBA(s) may mean system performance and/or redundancy is not optimal.HBA % is not connected.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorNone.A chain of enclosures connected at both ends to the same HBA gives a single point of failure.Chain of enclosures is connected to the same HBA at both ends (% %).Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorNone.Too long a chain of enclosures may cause degraded system performance.Cable on HBA % through % has %.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorNone.Connecting to an unexpected enclosure may mean path redundancy to associated disks is unavailable and system performance may be degraded.Connected to unexpected enclosure: Seeing: % -> % Expected: % -> %.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMinorNone.Connecting to the wrong receptacle is not a supported configuration.Connected to wrong receptacle: Seeing: % -> % Expected: % -> %.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorNone.A SAS cable is missing. Path redundancy to associated disks is unavailable and system performance may be degraded.Missing cable - % -> %.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.FaultMajorNone.A SAS cable has one or more faulty physical links (PHYs). System performance may be degraded.Faulty cable - % pm:% -> % pm:%.Use 'fmadm faulty' to provide a more detailed view of this event. Please refer to the associated reference document at %s for the latest service procedures and policies regarding this diagnosis.